Clean backup for PCs, POS & networks
Compact UPS with automatic voltage regulation. Keeps computers, cash registers, routers and CCTV running through power cuts and voltage swings — with sockets made for your market.
How big a UPS do I need?
Add the devices you want to protect. We add a 25% safety margin and suggest the right capacity.
Add a device to see our recommendation.
Backup time is an estimate for new batteries at 25 °C. Offline UPS are designed for a few minutes up to half an hour — enough to save work and shut down safely.Offline & line-interactive range
No model matches — tell us what you need and we will suggest one.
Six socket standards, fitted at the factory
Every model can be built with the outlets your customers use — up to 10 per unit, no adapters needed.
Offline or line-interactive?
Offline (standby) UPS
- How it worksPasses mains through; switches to battery when power fails
- Voltage swingsBasic AVR on most models
- Transfer timeTypically 4–8 ms
- PriceLowest cost per VA
Best for: home PCs, routers, small shops with stable power
Line-interactive UPS
- How it worksCorrects high and low voltage without using the battery
- Voltage swingsMulti-step AVR, longer battery life
- Transfer timeTypically 2–6 ms
- PriceSlightly higher, better protection
Best for: offices, POS, CCTV, areas with unstable voltage
Compare models
| Model | GF400 | GF600 | GF800 | GF1000 | GS400 | GS600 | GS800 | GS1000 | GS1200 | GS1500 | GS2000 | GS3000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type | Offline | Offline | Offline | Offline | Offline | Offline | Offline | Offline | Offline | Offline | Offline | Offline |
| Capacity | 400VA/240W | 600VA/360W | 800VA/480W | 1000VA/600W | 400VA/240W | 600VA/360W | 800VA/480W | 1000VA/600W | 1200VA/720W | 1500VA/900W | 2000VA/1200W | 3000VA/1800W |
| Input voltage range | 81-145Vac or 162-268/170-280Vac | 81-145Vac or 162-268/170-280Vac | 81-145Vac or 162-268/170-280Vac | 81-145Vac or 162-268/170-280Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac | 81–134 Vac / 89–145 Vac or 140–290 Vac / 140–300 Vac |
| Output voltage | 110V/120Vac or 220V/230Vac | 110V/120Vac or 220V/230Vac | 110V/120Vac or 220V/230Vac | 110V/120Vac or 220V/230Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac | 110/120 Vac or 220/230 Vac |
| Waveform (battery mode) | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave | Simulated Sine Wave |
| Transfer time | Typical 2-6ms, 10ms max | Typical 2-6ms, 10ms max | Typical 2-6ms, 10ms max | Typical 2-6ms, 10ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max | Typical 2–8 ms, 13 ms max |
| Battery | 12V6AH × 1 | 12V7AH × 1 | 12V8AH × 1 | 12V9AH × 1 | 12V4.5AH×1 | 12V7AH×1 | 12V9AH×1 | 12V7AH×2 | 12V7AH×2 | 12V9AH×2 | 12V9AH×2 | 12V9AH×4 |
| Recharge time | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity | 8 hours recover to 90% capacity |
| Interface | Support windows xp/vista, windows 7/8/11 and MAC | Support windows xp/vista, windows 7/8/11 and MAC | Support windows xp/vista, windows 7/8/11 and MAC | Support windows xp/vista, windows 7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC | USB/RS232 port (optional); supports Windows XP/Vista/7/8/11 and MAC |
| Dimensions (mm) | 285 × 193 × 103 | 285 × 193 × 103 | 285 × 193 × 103 | 285 × 193 × 103 | 255×86×140 | 255×86×140 | 306×86×140 | 306×86×140 | 345×123×189 | 345×123×189 | 345×123×189 | 397×148×235 |
| Net weight (kg) | 4.5 | 4.9 | 5.5 | 6.1 | 4 | 4.7 | 5.5 | 8.7 | 9.6 | 11.2 | 11.9 | 19 |
| Sockets (default) | 5 × Universal | 5 × Universal | 5 × Universal | 5 × Universal | — | — | — | — | — | — | — | — |